| A2 |
Communication can be speeded up in the following ways:
|
| |
(1) |
Increase the baud rate.
For MONITOUCH, go to the [Temp. Control/PLC2Way Comm. Setting] dialog ([System Setting] -> [Temp. CTRL/PLC2Way Comm. Setting]) and set [Baud Rate].
|
| |
|
When changing the baud rate for MONITOUCH, also change the counterpart setting for the temperature controller. |
| |
|

|
| |
|
|
| |
(2)
|
If multiple temperature controllers are connected, establish communications to all of them. As a result, recovery checks made for ports where communication is down are not required. |
| |
|
|
| |
(3) |
In place of setting the temperature controller memory directly in the screen data, use [Temp. CTRL/PLC2Way Network Table] dialog. |
| |
|
[Through the dialog, read the data from the temperature controller memory into the internal memory and set the internal memory in the screen data. |